How to Correctly Apply CryoSTUCK® Labels

CryoSTUCK labels can be applied at -80°C, ideally done on dry ice. Wipe away excess frost, and apply the label starting with the left edge, then press the label securely into position along the vials’ entire circumference.

How to apply thermal-transfer CryoSTUCK labels

How to apply laser CryoSTUCK labels

How to apply DYMO-compatible CryoSTUCK labels

 

Preserving the integrity of biological samples is vital, especially when labeling multiple vials. You don’t want to open and close your tank or freezer too many times or let your samples thaw on the bench. We recommend you do your labeling in batches and always set your samples in an insulated container of dry ice to preserve the temperature at -80°C. This is recommended as CryoSTUCK labels are meant to be applied at a minimum temperature of -80°C. So, if labeling vials stored in liquid nitrogen, dry ice will allow you to work comfortably and ensure the temperature of the samples does not rise to the point of thawing. Allow your tubes to equilibrate on dry ice for at least 5 minutes before labeling.

How to Apply Thermal-Transfer CryoSTUCK Labels

Our roll format CryoSTUCK® labels require an overlap of at least 0.25” to produce a secure adhesion to frozen vials and tubes. Ensure that your labels and vials allow for such overlap to guarantee the best adhesion and certify the cryo label will remain affixed on the frozen vials.

For optimal adhesion, wipe away any visibly accumulated frost with a clean lint-free disposable wipe (e.g: KimWipe™). Avoid excessive contact with the label adhesive during application. Apply the edge of the label first and press firmly to anchor it. If you have a wrap-around CryoSTUCK, apply the printable area first. Then press the label securely into position along the vials’ entire circumference. The vials can be stored in liquid nitrogen (-196°C), or ultra-low temperature freezers (-80°C) immediately following label application, requiring no cure time.

How to Apply Laser CryoSTUCK Labels

Our laser format CryoSTUCK® labels do not require an overlap to produce a secure adhesion to frozen vials and tubes. Nevertheless, please follow these steps to guarantee the best adhesion and certify the cryo label will remain affixed on the frozen vials.

To ensure proper application of these labels and their permanent adherence in ultra-low temperature storage (-80°C to -196°C), please wipe the surface of the vial/tube with a clean lint-free disposable wipe (e.g: KimWipe™) prior to affixing the label to remove excess frost. Avoid excessive contact with the label adhesive during application. Apply the edge of the label first and press firmly to anchor it. Then press the label securely into position along the vials’ entire circumference. The vials can be stored in liquid nitrogen or ultra-low temperature freezers immediately following label application, requiring no cure time.

How to Apply DYMO-Compatible CryoSTUCK Labels

To ensure proper application of these labels, wipe the surface of the vial/tube with a clean lint-free disposable wipe (e.g: KimWipe™) prior to affixing the label to any visibly accumulated frost. While avoiding excessive contact with the label adhesive apply the edge of the label first, pressing firmly to anchor it, and then apply the label securely into position along the vials’ entire circumference.

Our DYMO-compatible CryoSTUCK® labels do not require an overlap to produce a secure adhesion to frozen vials and tubes. The cryo vials can be returned to storage in liquid nitrogen (-196°C), or ultra-low temperature freezers (-80°C) immediately following label application, requiring no cure time.